QCM922A Quartz Crystal Microbalance and EQCM
QCM922A determines a small mass change by measuring resonance frequency and can coordinate to electrochemical studies

Product Details
- The QCM922A extends bandwidth for high sensitivity, up to 30MHz
- Analog outputs for easily integration with our potentiostats for coordinated data acquisition
- High-speed data acquisition, up to 100 data points per second
- A small footprint, light weight and USB 2.0 communication make for easy setup anywhere in the lab
Our QCM Family includes the main unit, interface cable and a variety of resonators, cells and software.
Application examples include:
- Measurement of biopolymer interactions, such as proteins
- Real-time monitoring of the formation and decomposition of thin films
- Evaluation of lithium ion battery electrodes
- Corrosion analysis
- Quantitative evaluation of the process of surfactant adsorption
- Measurement of film thickness in electroplating and electroless plating
- Analysis of structural changes by measurement of the frequency characteristics of the admittance
WinQCM and QCMAdm Software: Potentiostats with external analog outputs for potential and current can be connected to the QCM922A via the Analog Inputs, allowing data to be acquired in the optional WinQCM software. Optional QCMAdm Software can be used to measure the frequency response characteristics of the resonator.
| Specifications | QCM922A |
|
| Resonance Frequency Range | 5 MHz – 30 MHz (resolution: 0.01 Hz) | |
| Resonance Resistance Range | 1 Ω – 10 kΩ (resolution: 0.01 Ω) | |
| Resolution | 0.01 Hz | |
| Gate Time |
Variable (10 ms, 20 ms, 100 ms, 1 s, 10 s) | |
| Part Number | Description | |
| Resonator Holders | ||
| QA-CL3 | Dip Cell Resonator Holder | |
| QA-CL4 | Well Cell Resonator Holder - 0.750mL | |
| QA-CL6 | Flow Cell - 0.090mL | |
Software |
||
| WINQCM | Windows Quartz Crystal Microbalance Software | |
Cells |
||
| RG100 | Electrochemical Cell Bottom for use with QCM922 (requires K0264 cell kit) |
|
| QCMCELL | Kit QCM Cell Kit includes K0264 Micro-Cell Kit and RG100 |
|
| Resonators | ||
| QA-A9M-AL(M)-25 25 | 25 Aluminum Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-AL-25 | 25 Aluminum Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-AU(M)(SEP)-25 | 25 Gold Resonators, Mirror Finish (0.06 µm roughness), Separated |
|
| QA-A9M-AU(M)-25 | 25 Gold Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-AU(SEP)-25 | 25 Gold Resonators, Standard Finish (0.6 µm roughness), Separated |
|
| QA-A9M-AU-25 | 25 Gold Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-C(M)-25 | 25 Carbon Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-C-25 | 25 Carbon Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-CU(M)-25 | 25 Copper Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-CU-25 | 25 Copper Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-ITO(M)(SEP)-25 | 25 ITO (Indium Tin Oxide) Resonators, Mirror Finish (0.06 µm roughness), Separated |
|
| QA-A9M-ITO(M)-25 | 25 ITO (Indium Tin Oxide) Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-NI(M)-25 | 25 Nickel Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-NI-25 | 25 Nickel Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-PT(M)(SEP)-25 | 25 Platinum Resonators, Mirror Finish (0.06 µm roughness), Separated |
|
| QA-A9M-PT(M)-25 | 25 Platinum Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-PT(SEP)-25 | 25 Platinum Resonators, Standard Finish (0.6 µm roughness), Separated |
|
| QA-A9M-PT-25 | 25 Platinum Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-SIO2-S(M)-25 | 25 Silicon Oxide Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-SUS304(M)-25 | 25 Stainless Steel 304 Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-SUS304-25 | 25 Stainless Steel 304 Resonators, Standard Finish (0.6 µm roughness) |
|
| QA-A9M-SUS316L(M)-25 | 25 Stainless Steel 316L Resonators, Mirror Finish (0.06 µm roughness) |
|
| QA-A9M-SUS316L-25 | 25 Stainless Steel 316L Resonators, Standard Finish (0.6 µm roughness) |
|
| Software | ||
| WinQCM | Windows Quartz Crystal Microbalance Software | |
Videos
Watch video demonstrations of the QCM922A Quartz Crystal Microbalance and EQCM

Support
Need Help? We’re Here for You. Our global support team and partners worldwide are ready to assist you.

Let’s Talk
Our specialists can help you identify the right approach, technology, or instrument for your application.