1296A Dielectric Interface System

1296A is interface to extend compatibility of 1260A and 12xx series to high impedance samples 


Electrochemical Accessories 
Our materials accessories

     SMaRT software

  • Highlights +


    • High impedance range to 100 TOhms for dielectrics and insulators
    • Wide frequency range from 10 MHz to 10 µHz
    • Compatible with 1260A and other 12xx series Frequency Response Analyzers
    • Sample-Reference Mode for high accuracy capacitance, phase and Tan delta

  • 1296A Family Overview +


    1296A Family Overview
    System Overview

    Analyzing low conductivity, low loss materials stretches the capabilities of even the best impedance analyzers. Used alone, they lack the sensitivity required for accurate measurements, especially at low frequencies.

    The 1296A Dielectric Interface overcomes these limitations to give you fast, accurate and repeatable impedance measurements over 12 decades of frequency, yielding valuable insights into the characteristics of a wide range of materials, including polymers, ceramics, ion conductors, dielectrics, piezo/ferroelectrics, display materials etc. Coupled with easy-to-use software, a 1296A-based system takes care of experimental technique and lets you concentrate on interpreting the results.

    The 1296A enhances the capabilities of Solartron Analytical’s renowned 1260A and 1255A FRAs to cope with ultra-low current and capacitance levels experienced in testing dielectric materials, enabling:
    • Impedance measurements to exceed 100 TΩ (1014Ω)
    • Accurate tan delta measurements down to <10-4
    • Frequency range from 10 μHz up to 10 MHz
    • AC signal and DC bias voltages up to 10,000 V (with external psu or amplifier) for dielectric breakdown and linearity studies
    Highly accurate reference capacitors are built in to 1296A for sample/reference testing, or you can choose to use an external reference, offering unrivaled flexibility to meet almost every measurement need. Support for temperature and DC controllers is integral to the measurement software, further increasing the scope for materials analysis.

    Temperature Options
    • 129610A Cryostat System covering 5 K to 600 K, complete with solid and liquid sample holder for testing polymers, rubber, pharmaceuticals, etc.
    • Furnace system covering room temperature to 1200º C, complete with sample holder for testing ceramics, composites, glasses etc.
    • Room temperature sample holder for solids and liquids
  • Applications +


    Applications, Dielectrics
    Defining Dielectrics

    Many materials have the properties of low conductance (high impedance) and low loss. They are often referred to as dielectrics, although many materials not normally considered as dielectrics exhibit these properties.

    One popular technique for analyzing such materials is Impedance Spectroscopy - measuring the electrical impedance over a range of frequencies. The impedance is related to the conductivity and capacitance of the material, and these parameters can in turn be related to the molecular activity of the material.

    When an alternating voltage is applied to a dielectric sample, some energy is stored by the capacitance, and some is dissipated by the resistance effects.

    The resulting current in the sample will exhibit a phase lag, δ. In materials research, the capacitance effect is known as the permittivity (or dielectric constant) ε’, and the resistive effect as dielectric loss, ε”. Tan δ, the dissipation factor equals ε”/ε’.

    In materials where ε” is very small and ε’ large, the resolution of tan δ becomes critical if an accurate measurement is to be made. The 1296A overcomes this by taking a reference measurement on precision capacitors which are automatically substituted for the sample; a second measurement is made, this time on the sample itself. The two results are used to derive an accurate measurement of the permittivity of the material - in effect, the first measurement is used to eliminate the effects of extraneous capacitance.

    Applications

    The range of applications for a 1296A system is huge, and includes the investigation of:
  • Relaxation processes in the molecular dynamics of liquid crystals, polymers and liquids
  • Charge transport in semiconductors, organic crystals, ceramics etc.
  • Analysis of chemical reactions, polymerization and curing processes
  • Non-linear electrical and optical effects
  • Novel gas and liquid sensors
  • Characterization of insulating and semiconductor materials
  • Quality control in the production of insulators, printed circuit boards, etc.
  • Fuel cell/battery materials
  • Brochure and Manual +

  • Differentiated Specifications +



     Specifications 1296A+1260A/1255A 1296A+1250E 1296A+1253A
    Frequency Range
    10 MHz to 10 µHz
    65 kHz to 10 µHz
    20 kHz to 1 mHz
    Signal Amplitude
    Up to 7 V RMS
    For signals >3Vrms, an internal amplifier is used,
    and signal amplitude + DC bias must not exceed 10V peak
    Up to 10 V RMS Up to 10 V RMS
         
    Current Measurement
    100 mA to 1 fA
    Tan delta range  < 10-4 to 103 (Reference Mode)
    Impedance Range
    100 Ω to > 100 TΩ (1014Ω) 
    Capacitance Range > 0.1 F to 1 pF 
       
     Software Provides control of FRA, 1296A and optional temperature controller, DC bias and AC signal amplifiers 
     Result parameters  Z*, Y*, ε*, C* (real, imaginary, magnitude, phase, tan δ)
     plotted versus frequency, time, temperature, bias, ac level 
     on  Bode, complex plane


    1296A Typical accuracy
  • Accessories +

  • Video +

    Watch video demonstrations of the 1296A Dielectric Interface System