1260A Impedance Analyzer

1260 Frequency Response Analyzer
The model 1260A Impedance/Gain-Phase Analyzer is - without doubt - the most powerful, accurate and flexible Frequency Response Analyzer available today. In daily use by leading researchers wherever measurement integrity and experimental reliability are of paramount importance, the 1260A’s solid reputation is frequently endorsed in published research papers in fields such as:

  • Corrosion studies
  • Battery research and fuel cells
  • Solar cells
  • LCD's
  • Bio-materials
  • Ceramics / composites
  • Electronic component development
  • Civil engineering
Huge frequency range
Spanning 10 μHz to 32 MHz with 0.015 ppm resolution, 1260A provides excellent coverage for virtually all chemical and molecular mechanisms - all in a single instrument.

Unbeatable accuracy
With an accuracy of 0.1%, 0.1°, measurements can be made with complete confidence, and even the most subtle changes in sample behavior detected and quantized.

Noise free analysis
1260A uses Solartron Analytical’s patented single-sine correlation technique, which inherently removes the noise and harmonic distortion which plagues lesser instruments.
  • Frequency resolution: 1 in 65 million (0.015 ppm)
  • 0.1%, 0.1° accuracy – unsurpassed by any similar instrument
  • Resolution to 0.001 dB, 0.01° - capturing every detail
  • Measures impedances >100 MΩ
  • 2-, 3- and 4-terminal measurement configurations
  • Polarization voltage up to ±40.95 V
  • Renowned ZPlot software package simplifies experiments and optimizes throughput
Systems
When combined with other products from Solartron Analytical’s range, including well-proven application software, the 1260A can form the heart of an advanced electrochemical and materials measurement system, to provide superb accuracy, flexibility and reliability - even for the most complex research problems.

Impedance measurement
Virtually every liquid and solid is able to pass current when a voltage is applied to it. If a variable (ac) voltage is applied to the material, the ratio of voltage to current is known as the impedance. The measured impedance varies with the frequency of the applied voltage in a way that is related to the properties of the liquid or solid. This may be due to the physical structure of the material, to chemical processes within it or a combination of both.

The advantages of impedance measurement over other techniques include:
  • Rapid acquisition of data
  • Accurate, repeatable measurements
  • Non-destructive
  • Highly adaptable to a wide variety of different applications.
  • Ability to differentiate effects due to electrodes, diffusion, mass/charge transfer by analysis over different frequency ranges
  • Equivalent circuit/modeling techniques for detailed analysis of results
  • Documents +

  • Specifications +


    Generator Voltage Current mode
    ac Amplitude ≤10MHz
    >10MHz
    0 to 3V rms
    0 to 1V rms
    0 to 60mA rms
    0 to 20mA rms
    Maximum ac resolution 5mV 100µA
    dc bias range ±40.95V ±100mA
    Maximum dc resolution 10mV 200µA
    Frequency range:10µHz to 32MHz, max resolution: 10µHz frequency (log or lin) ac/dc voltage, ac/dc current
    Sweep types frequency (log or lin) ac/dc voltage, ac/dc current
    Maximum voltage hi to lo: ±46v peak, lo to ground: ±0.4V peak
    Maximum current ±100mA peak
    Impedance lo to ground: 100kΩ, <10nF
    Connection single BNC, floating shield
    Output disable contact closure or TTL logic 0

    Input System Voltage (2x) Current
    3 independent analyzers operating in parallel
    Ranges 30mV, 300mv, 3V 6µA, 60µA, 600µA, 6mA, 60mA
    Maximum resolution 1µV 200pA
    Full Scale Peak ±5V ±100mA
    Inputs projected to ±46V ±250mA
    Connections single/differential BNC single BNC
    Shields floating/grounded -
    Coupling dc or ac (-3dB at 1Hz) dc or ac (-3dB at Hz)
    Input impedance
    Hi to shield 1Mohm, <35pF ≥600µA range, 1Ω
    Shield to ground 10kohm, 330pf <600µA range, 50Ω
    Limits of error Ambient temperature 20±10ºC, integration time >200ms. Data valid for one year after calibration.
    Results
    Variable frequency, ac amplitude, dc bias
    Measured parameters voltage gain, phase, real, imaginary, Z, R, X, Y, G, B, V, I group delay, C, L, Q, D
    Power supply 90 to 126v, 198 to 252v, 48 to 65Hz
    Power consumption 230VA
    Dimensions (w x h x d) 432mm x 176mm x 573mm (17in x 6.93in x 22.56in)
    Weight 18kg (40lbs)
    Operating temp. rate 0 to 50ºC (32 to 122ºF)
    Limit of errorGain-phase measurments Applies to all ranges at >10% full scale

  • Options +


    560 001 160 National Instruments USB-GPIB Adapter
    31203B Shielded GPIB cable 6' (2 meter)
    359 902 120 Reverse Slimline Adapter (National Instruments 182770-00) required to use P/N 560 001 160 with a standalone FRA
          
  • Software +

    • SMaRT Impedance Measurement Software

      • Wide range of materials test AC techniques (impedance, capacitance, admittance, permittivity and Mott-Schottky) for all types of materials including dielectrics, insulators and electronic materials
      • Full support of 12xx materials test products including 1260A Impedance Analyzer and 1296A Dielectric Interface
      • Integrated temperature control including custom designed cryostats and furnaces

      Keep Reading

    • ZPlot Software

      • Wide range of potentiostatic and galvanostatic electrochemical techniques, including cyclic voltammetry, galvanic pulse, impedance, AC voltammetry and Mott-Schottky
      • Full support of 12xx series Impedance and Frequency Response Analyzers including 1260A, 1255B, 1252A, 1250E, 1253A
      • Full support of Power Boosters up to 100 V and 100 A for DC and EIS testing of high power batteries/ fuel cells and for anodization and electroplating

      Keep Reading

    • ZView Software

      • ZView is the companion EIS data analysis software for ZPlot
      • Multiple display formats (impedance, admittance, capacitance, permittivity and electrical modulus)
      • Comprehensive data analysis capabilities include an extensive library of equivalent circuit data fit models – R, C, L, Warburg, Distributed Elements

      Keep Reading

    • CellTest 1470-1455 Software & Firmware Upgrades

      • Wide range of voltage and current controlled battery/fuel cell/supercapacitor test techniques, including charge / discharge, ramps, pulses and impedance (if FRAs are connected).
      • Full support of CellTest multichannel potentiostat products including 1470E, 1470A/1480A
      • Full support of 1455A/1451A for parallel impedance, and 12xx FRAs for multiplexed impedance
      • Power Boosters for DC and EIS testing of high power batteries/ fuel cells and for anodization and electroplating

      Keep Reading

    • MultiStat Software

      • Wide range of potentiostatic and galvanostatic test techniques for battery/fuel cell/supercapacitor, including charge/discharge, cyclic voltammetry, galvanic pulse, and impedance (if FRAs are connected).
      • Full support of CellTest multichannel potentiostat products including 1470E, 1470A/1480A
      • Full support of 1455A/1451A for parallel impedance, and 12xx FRAs for multiplexed impedance
      • Power Boosters for DC and EIS testing of high power batteries/ fuel cells and for anodization and electroplating

      Keep Reading

    • Frequency Response Analyzer Software

      • Frequency response / transfer function analysis software
      • Simple set up of experiment parameters including frequency range and AC amplitude
      • Data analysis on multiple displays with cursor facilities and with data export to Microsoft Excel
      • Support of 12xx frequency response analyzers including 1260A Impedance Analyzer (for voltage measurements only – not impedance)